Specifications
| Rated frame current Inm (A) | 250 | 250 | 320 | 400 | 630 | 800 | |||||||||
| Model | DAM3PV -250 |
DAM3PV -250HU |
DAM3PV -320HU |
DAM3PV -400HU |
DAM3PV -630HU |
DAM3PV -800HU |
|||||||||
| Rated current In (A) | 100A、125A、 140A、160A、 180A、200A、 225A、 250A |
125A、 140A、 160A、 180A、 200A.、225A、 250A |
280A、 315A、 320A |
225A、250A、 315A、350A、 400A |
400A、500A、 630A |
630A、700A、 800A |
|||||||||
| Number of poles | 2 | 3 | 4 | 2 | 3 | 2 | 3 | 4 | 4 | 4 | |||||
| Rated working voltage Ue (V) DC | 500 | 750 | 1000 | 1000 | 1500 | 1000 | 1500 | 1000 | 1250 | 1500 | 1000 | 1500 | 1000 | 1250 | 1500 |
| Rated insulation voltage Ui (V) | 1250 | 1250 | 1500 | 1250 | 1500 | 1500 | 1500 | 1500 | |||||||
| Rated impulse withstand voltage Uimp(kV) | 12 | 8 | 12 | 8 | 12 | 12 | 12 | 12 | |||||||
| Ultimate short-circuit breaking capacity icu (kA) |
40 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |||||||
| Service short-circuit breaking capacity Ics (kA) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |||||||
| Wiring method | See attached diagram |
See attached diagram |
See attached diagram |
See attached diagram |
See attached diagram |
See attached diagram |
|||||||||
| Installation method | Fixed and plug-in |
Fixed and plug-in | Fixed and plug-in | Fixed and plug-in | Fixed and plug-in | Fixed and plug-in | |||||||||
| Mechanical life (total number of times) | 8000 | 8000 | 8000 | 5000 | 5000 | 3000 | |||||||||
| Electrical life (total number of times) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |||||||||
| With isolation characteristic or not | Yes | Yes | Yes | Yes | Yes | Yes | |||||||||
| Allowable usage ambient temperature (“C) | -5℃~+40℃ | -5℃~+40℃ | -5℃~+40℃ | -5℃~+40℃ | -5℃~+40℃ | -5℃~+40℃ | |||||||||
| Protection level | IP20 | IP20 | IP20 | IP20 | IP20 | IP20 | |||||||||
| Accessory attachable | Auxiliary,shunt, alarm,manual operation, electric operation |
Auxiliary,shunt. alarm,manual operation, electric operation |
Auxiliary,shunt, alarm, manual operation, electric operation” |
Auxiliary,shunt, alarm,manual operation, electric operation |
Auxiliary,shunt, alarm, manual operation, electric operation |
Auxiliary,shunt, alarm,manual operation, electric operation |
|||||||||
| Instantaneous action value | 10in | 10In | 10ln | 10in | 10in | 10in | |||||||||
| Arc distance (mm) | ≤50 | ≤50(0 with cover) | ≤50 (0 with cover) | ≤50 (0 with cover) | ≤50 (0 with cover) | ≤50(0 with cover) | |||||||||
| Outline dimension (L×W×H)(mm) | 2P:165×72×127 3P:165x107x127 4P:165×142×127 |
2P:180×76×126 3P:180x107x126 |
2P:180×76×126 3P:180x107x126 |
258×200×107 | 280×280×116 | 280×280×116 | |||||||||
Product Description
The DAM3PV series moulded case circuit breaker is suitable for DC power grid circuit and solar photovoltaic system with maximum rated voltage of DC1500V and rated current of 800A. It has overload and short circuit protection function,used to distribute electrical energy and protect circuit and power equipment from overload, short circuit and other faults.
Product Features
Contact Us