    Product Description

    The rated current of the Dada DAM3-250 molded case circuit breaker can reach up to 250A. These electrical devices are suitable for power distribution circuits with an alternating current of 50-60Hz and a rated operating current to 1000A. They can also be used in electric motors for infrequent starting and overload protection as well as protection against short circuiting and undervoltage conditions.Compared to the DAM1 series, the DAM3 series are designed for smaller volume, higher breaking capacity, offering better energy savings.

    DAM3-250 4P MCCB moulded case circuit breaker

    Specifications

    Electrical parameters of DAM3-250 molded case circuit breaker

    Rated current of frame size Inm [A]   250
    Rated current [A] 100-250 100-225
    Number of poles 2002/3/4
    Rated operating voltage (AC)50-60HZ [V] 400/690
      DC [V] 250/1000
    Rated impulse withstand voltage Uimp [KV] 8
    Rated insulation voltage Ui [V] 750
    Test voltage at industrial frequency for 1 min [V] 3000
    Rated ultimate short-circuit breaking capacity Icu [KA] B C N S
    (AC)50-60HZ 220/230V [KA] 30 36 50 75
    (AC)50-60HZ 400/415V [KA] 18 25 36 50
    (AC)50-60HZ 690V [KA] 6 8 12 15
    (DC)250V-2 Poles in series 18 22 30 40
    (DC)500V-2 Poles in series 9 12 15 20
    (DC)750V-4 Poles in series 16 18 22 30
    (DC)1000V-4 Poles in series 13 15 18 25
    Rated service short-circuit breaking capacity, Ics [KA]        
    (AC)50-60HZ 220/230V [%Icu] 60% 60% 60% 50%
    (AC)50-60HZ 400/415V [%Icu] 60% 60% 60% 50%
    (AC)50-60HZ 690V [%Icu] 60% 60% 60% 50%
    category of utilization (EN 60947-2) A
    Isolation condition Bitmap
    Reference standard IEC/EN 60947-2/GB 14048.2
    Interchangeability Bitmap
    Versions Fixed Bitmap
      Plug-in Bitmap
      Draw-out

    Physical parameters DAM3-250 molded case circuit breaker

    Endurance Total cycles 10000
      Electrical endurance 1500
      Mechanical endurance 8500
    Basic dimensions-fixed version 3/4 Poies W[mm] 70(2P) /104 /139
      3/4 Poies H[mm] 59 62.5
      H1[mm] 78.5 82
      3/4 Poies L[mm] 139

    Product Features

    undefined
    The DAM3-250 molded case circuit breaker automatically cuts off the current when the current exceeds the release setting. The molded case refers to the plastic insulator used as the frame of the device to insulate the conductor and the metal grounding component.

    Contact Us

    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Support Center 24/7
    0086 173 1658 0160
    Write to Us
    yjq@cdada.com
    Our Location
    171 Yezhuang road, Fengxian District, Shanghai, China
    Related Products
    Shanghai DADA Electric Co., Ltd.
    Acknowledged as one of the most respected nationwide manufacturers and exporters of low voltage circuit breakers in China.
    Social media
    CONTACT US
    Contact Person: Joker Yang
    Tel: +86 173 1658 0160
    Contact Person: Charlotte Weng
    Tel: +86 151 6747 7792
    Address: 171 Yezhuang Road, Fengxian District, Shanghai, China
    Customer service
    detect