DAB6-63 are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) - C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) - D characteristic switches; Miniature circuit breaker DAB6-63 are recommended for use in electrical distribution panels of residential and public buildings.
Product Description
● wo types of short circuit protection.
● Wide range of operating temperatures from –40 to +50° С.
● Updated wider engagement lever with improved contact area.
● Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.
Specifications
|
MCB DAB6-63 |
|||||||
|
For protection of general power distribution (IEC/EN 60898-1) |
1P |
2P |
3P |
4P |
|||
|
Poles |
|||||||
|
Electrical performance |
|||||||
|
Functions |
short circuit protection,overload protection,isolationg,control |
||||||
|
Rated frequency f Hz |
50-60Hz |
||||||
|
Rated working voltage Ue V AC |
230/400 |
400 |
|||||
|
Rated current In A |
6,10,16,20,25,32,40,50,63 |
||||||
|
Rated insulated voltage Ui V |
500 |
||||||
|
Impulse withstand voltage Uimp kV |
4 |
||||||
|
Instantaneous tripping type |
DAB6-63N |
B/C/D |
|||||
|
DAB6-63H |
B/C/D |
||||||
|
Rated short circuit Icn(kA) |
DAB6-63N |
4.5 |
|||||
|
DAB6-63H |
6 |
||||||
|
Release type |
Thermal magnetic type |
||||||
|
Service life(O~C) |
Mechanical |
Actual value |
20000 |
||||
|
Standard value |
4000 |
||||||
|
Electrical |
Actual value |
8000 |
|||||
|
Standard value |
4000 |
||||||
|
Connection and installation |
|||||||
|
Protection degree |
IP20 |
||||||
|
Wire mm² |
1~35 |
||||||
|
Working temperature |
-5~+40℃ |
||||||
|
Resistance to humidity and heat |
Class 2 |
||||||
|
Altitude above sea |
≤2000 |
||||||
|
Relative humidity |
+20℃ ,≤90% ;+40℃ ,≤50% |
||||||
|
Pollution degree |
2 |
||||||
|
Installation environment |
Avoid obvious shock and vibration |
||||||
|
Installation class |
ClassⅡ , ClassⅢ |
||||||
|
Mounting |
DIN35 rail |
||||||
|
Combination with accessories |
|||||||
|
Auxiliary contact |
Yes |
||||||
|
Alarm contact |
Yes |
||||||
|
Shunt release |
Yes |
||||||
|
Undervoltage release |
Yes |
||||||
|
Auxiliary contact+Alarm contact |
Yes |
||||||
|
Dimensions(mm) (WxHxL) |
a |
17.5 |
35 |
52.5 |
70 |
||
|
b |
80.2 |
80.2 |
80.2 |
80.2 |
|||
|
c |
76.5 |
76.5 |
76.5 |
76.5 |
|||
Product Features