loading

CDADA - Professional circuit breaker manufacturer since 1984

DAB7-100 8kA MCB Switch Miniature Circuit Breaker 1
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 2
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 3
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 4
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 5
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 6
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 7
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 1
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 2
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 3
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 4
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 5
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 6
DAB7-100 8kA MCB Switch Miniature Circuit Breaker 7

DAB7-100 8kA MCB Switch Miniature Circuit Breaker

The DAB7-100 miniature circuit breaker is developed specifically to GB 10963 and IEC60898 standards. The circuit breakers boast outstanding stability, short circuit protection, overload protection, short opening time, and high breaking capacity index all in one miniature design.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    The circuit breakers are installed for overload protection of contactors, relays, and other electrical equipment.Main functions: short circuit protection, overload protection, and electrical isolation.

    (148)
    (152) (2)

    Specifications

    Technical parameter of DAB7-100 8kA miniature circuit breaker

    Standard of conformity: IEC60898, GB10963

    Rated voltage: 230/400V, 50HZ

    Rated breaking capacity: 10KA (6-63A), 8KA (80-100A)

    Protection grade: IP20

    Flame retardant grade: grade2

    Endurance (power-driven): no less than 8,000 times of opening

    Endurance (manual operation): no less than 20,000times of opening

    Mechanical parameters of DAB7-100 8kA miniature circuit breaker

    Electric wire: 1~35mm2

    Connection mode: There are two kinds of connection, direct connection to the connecting plate, or connected by copper wire

    Suitable size for terminal: The thickness of connecting plate is 0.8-2mm, the sectional area of copper conductor is 1-25mm2

    Operating temperature: -5~+40℃

    Altitude: ≤2000

    Relative humidity: +20℃,≤90%; +40℃,≤50%

    Class of pollution: 2

    Installation method: Using 35mm IEC standard

    Installation environment: Avoid obvious shock and vibration

    Installation grade: grade II

    Guide rail: DIN35guide rail

    (149) (2)

    For protection of general power distribution (IEC/EN 60898-1)

    1P

    2P

    3P

    4P

    Poles

    Electrical performance

    Functions

    short circuit protection,overload protection,isolationg,control

    Rated frequency                        f                               Hz

    50-60Hz

    Rated working voltage              Ue                         V AC

    230/400

    400

    Rated current                            In                               A

    6,10,16,20,25,32,40,50,63,80,100

    Rated insulated voltage            Ui                  V

    500

    Impulse withstand voltage          Uimp                kV

    4

    Instantaneous tripping type

    DAB7-100N

    B/C/D

    DAB7-100H

    B/C/D

    Rated short circuit Icn(kA)

    DAB7-100N

    6

    DAB7-100H

    10

    Release type

    Thermal magnetic type

    Service life(O~C)

    Mechanical

     Actual value

    20000

     Standard value

    4000

    Electrical

     Actual value

    8000

     Standard value

    4000

    Connection and installation

    Protectiom degree

    IP20

    Wire                                             mm²

    1~35

    Working temperature

    -5 ~+40℃

    Resistance to humidity and heat

    Class 2

    Altitude above sea

    ≤2000

    Relative humidity

    +20℃ , ≤90% ;+40℃ , ≤50%

    Pollution degree

    2

    Installation environment

    Avoid obvious shock and vibration

    Installation class

    Class Ⅱ , Class Ⅲ

    Mounting

    DIN35 rail

    Combination with accessories

    Auxiliary contact

    Yes

    Alarm contact

    Yes

    Shunt release

    Yes

    Undervoltage release

    Yes

    Auxiliary contact+Alarm contact

    Yes

    Dimensions(mm)                                            (WxHxL)

    a

    18

    36

    54

    72

    b

    80

    80

    80

    80

    c

    72

    72

    72

    72

    Product Features

    undefined
    The DAB7-100 miniature circuit breaker is developed specifically to GB 10963 and IEC60898 standards.
    This series of circuit breaker accessories are specially designed for use in conjunction with DAB7 (63 frame) circuit breakers and are not intended to be used alone.
    undefined
    The circuit breakers boast outstanding stability, short circuit protection, overload protection, short opening time, and high breaking capacity index all in one miniature design.
    The four accessories are installed on the left side of DAB7-63 miniature circuit breakers, the DAB7-OF, DAB7-FB, DAB7-QY are fixed with screws, the DAB7-FL is fixed to both sides with tape, and at the same time can be installed with the guide rail.

    Contact Us

    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Support Center 24/7
    0086 173 1658 0160
    Write to Us
    yjq@cdada.com
    Our Location
    171 Yezhuang road, Fengxian District, Shanghai, China
    Related Products
    Shanghai DADA Electric Co., Ltd.
    Acknowledged as one of the most respected nationwide manufacturers and exporters of low voltage circuit breakers in China.
    Social media
    CONTACT US
    Contact Person: Joker Yang
    Tel: +86 173 1658 0160
    Contact Person: Charlotte Weng
    Tel: +86 151 6747 7792
    Address: 171 Yezhuang Road, Fengxian District, Shanghai, China
    Customer service
    detect