ALF series Miniature Circuit Breaker(MCB)

ALF are intended for protecting distribution and group systems having different loads: electric appliances, lighting – V characteristic switches; drives with moderate starting currents (compressor, fan group) - C characteristic switches; drives with high starting currents (hoisting mechanisms, pumps) - D characteristic switches; Miniature circuit breaker ALF are recommended for use in electrical distribution panels of residential and public buildings.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    Two types of short circuit protection.

    Wide range of operating temperatures from –40 to +50° С.

    Updated wider engagement lever with improved contact area.

    Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.

    undefined

    Specifications

    MCB ALF        
    For protection of general power distribution (IEC/EN 60898-1)
    Poles 1P 2P 3P 4P
    Electrical performance
    Functions short circuit protection,overload protection,insolation,control
    Rated frequency                        f                               Hz 50-60Hz
    Rated working voltage              Ue                         V AC 230/400 400
    Rated current                            In                               A 6,10,16,20,25,32,40,50,63
    Rated insulated voltage            Ui                  V 500
    Impulse withstand voltage          Uimp                kV 4
    Instantaneous tripping type ALF B/C/D
    Rated short circuit Icn(kA) ALF 4.5
    Release type   Thermal magnetic type
    Service life(O~C) Mechanical  Actual value 20000
     Standard value 4000
    Electrical  Actual value 8000
     Standard value 4000
    Connection and installation
    Protectiom degree IP20
    Wire                                             mm² 1~35
    Working temperature -5 ~+40℃
    Resistance to humidity and heat Class 2
    Altitude above sea ≤2000
    Relative humidity +20℃ , ≤90% ;+40℃ , ≤50%
    Pollution degree 2
    Installation environment Avoid obvious shock and vibration
    Installation class Class Ⅱ , Class Ⅲ
    Mounting DIN35 rail
    Combination with accessories
    Auxiliary contact Yes
    Alarm contact Yes
    Shunt release Yes
    Undervoltage release Yes
    Auxiliary contact+Alarm contact Yes
    Dimensions(mm)                                      (WxHxL)                      ALF series Miniature Circuit Breaker(MCB) 8 a 17.5 35 52.5 70
    b 80.2 80.2 80.2 80.2
    c 76.5 76.5 76.5 76.5

    Product Features

    undefined
    Excellent breaking ability
    Two types of short circuit protection.
    undefined
    Wide range of operating temperatures from –40 to +50° С.
    The four accessories are installed on the left side of DAB7-63 miniature circuit breakers, the DAB7-OF, DAB7-FB, DAB7-QY are fixed with screws, the DAB7-FL is fixed to both sides with tape, and at the same time can be installed with the guide rail.
    undefined
    Updated wider engagement lever with improved contact area.
    The mechanical connection between the circuit breaker and DAB7-, DAB7- FB, DAB7- FL, DAB7-QY transmission shaft should be flexible and compatible with the rest of the equipment.
    undefined
    Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.
    After DAB7-QY circuit breaker has been installed, it can only be closed when press the test button. And installer should shut off the circuit breaker and release the test button immediately, thus ensure the installation safely and correctly. Besides, the rated voltage should pass through the undervoltage trip at same time.

    Contact Us

    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Support Center 24/7
    0086 173 1658 0160
    Write to Us
    yjq@cdada.com
    Our Location
    171 Yezhuang road, Fengxian District, Shanghai, China
    Related Products
    Shanghai DADA Electric Co., Ltd.
    Acknowledged as one of the most respected nationwide manufacturers and exporters of low voltage circuit breakers in China.
    Social media
    CONTACT US
    Contact Person: Joker Yang
    Tel: +86 173 1658 0160
    Contact Person: Charlotte Weng
    Tel: +86 151 6747 7792
    Address: 171 Yezhuang Road, Fengxian District, Shanghai, China
    Customer service
    detect