M8LC Series Residual Current Circuit Breaker

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    1.Product usage

    The M8LC series residual current operated circuit breaker(hereinafter referred to as circuit breaker) is mainly suitable for distribution networks with frequency of AC 50Hz and rated working voltage of AC 400V.Used in three-phase four-wire power supply and consumption system with neutral point directly grounded, it has functions such as overload, short circuit, phase loss, overvoltage, undervoltage, residual current action protection, etc. It can protect circuit and electrical equipment from damage, and also provide protection for possible grounding fault and indirect personal contact in circuit.

    The product complies with GB/T14048.2,GB/T14048.4,GB/T32902 and GB/T22387 standard.

    2.Product feature

    2.1 Multiple functions

    It has protection functions such as residual current, overcurrent, short circuit, etc, as well as practical functions such as automatic reclosing, residual current display, realtime load current display, action status indication and trip data display. The product also has functions such as pluggable lightning protection module, four remote functions and special adapter. 

    2.2 Small volume

    The combination of electric operating mechanism and air circuit breaker has been transformed into an integrated type, with reduced installation location and simplified wiring. The operation method with configurable function characteristic can set the 

    required functions such as action current, breaking time and main circuit current according to the actual situation. 

    2.3 Intelligence

    The intelligent control circuit composed of single chip microprocessor can set and display load current, monitor the cause of fault trip, display fault parameters during trip, and query the total number of various fault trips. 

    2.4 Communicability (when this function is required during ordering)

    The communication type leakage circuit breaker can record and query detailed data such as the phase sequence that causes the trip, cause and trip time, and has the function of historical data recording; the communication series product adopts RS-485 communication port and have multiple communication protocols to choose from. It can establish communication function with intelligent distribution transformer terminal, upper computer, etc., and achieve remote parameter adjustment, information query and fault parameter download.

    3.Working environment and installation condition

    The ambient air temperature shall not exceed +40℃, and the average temperature value within 24 hours shall not exceed +35℃. The lower limit of the ambient air temperature is -20℃; Note: For working condition where the ambient air temperature is above +35℃ or below -20℃, the user should consult with the manufacturer.

    The altitude of the installation site shall not exceed 2000m;The maximum temperature is +40℃, and the relative humidity of the air does not exceed 50%. At lower temperature, there can be higher relative humidity. Special measures should be taken for occasional condensation caused by temperature changes;In a place without rain or snow erosion;

    The pollution level is 3;

    The maximum inclination of circuit breaker installation is ±5°;Installation category: The installation category of the main circuit of the circuit breakeris III, and the installation category of the auxiliary circuit and control circuit is II.

    The external magnetic field of the installation site shall not exceed 5 times the geomagnetic field in any direction.

    4.Model and meaning

    96F7721B-5EED-4282-8E0B-7A560482926F

    5. Main technical parameter

    Model and specification

    M8LC-125

    M8LC-250

    M8LC-400

    M8LC-630
    (increased capacity)

    M8LC-800

    Frame current In(A)

    125

    250

    400

    630

    800

    Overload long delay
    setting range IR (A)

    (0.4~1)In

    Rated residual operating
    current In(mA)

    30 (non delay type only)
    50/100/150/200/300/500/900/1000/OFFgraded adjustment delay type, automatic tracking

    Ultimate non driving time (s)

    0.06  0.1  0.2 optional settings

    Number of poles

    3P+N; 4P

    Rated insulation voltage Ui(V)

    AC1000

    Rated impulse withstand
    voltage Uimp (kV)

    125/250/  8KV             400/630/800  12KV

    Rated working voltage Ue(V)

    AC380/400/415 50Hz

    Rated ultimate short-circuit
    breaking capacity Icu (kA)

    M50/H85

    M65/H85

    M65/H85

    Rated service short-circuit
    breaking capacity Ics (kA)

    M35/H65

    M50/H65

    M50/H65

    Rated  short time withsatnd current Icw

    5kA/1S

    10kA/1S

    10kA/1S

    Selective category

    Category B

    Category B

    Category B

    Rated residual short-circuit making
    and breaking capacity I▲ m(kA)

    25%Icu

    Reclosing interval time (s)

    20~60(manual closing is not limited by time interval)

    6. Outline and installation dimensio

    49A03A98-5594-43bb-A58C-69B01CE76071

    Specification

    Outline dimension mm

    Installation dimension mm

    External copper plate dimension

    Installation screw dimension mm

    W

    L

    H

    A

    B

    D

    C

    M8LC- 125

    122

    220

    122

    199

    60

    30

    16

    4x45

    M8LC -250

    142

    240

    135

    201

    70

    35

    22

    M8LC-400(630ZR)

    196

    335

    177

    272

    96

    48

    30

    6X70

    M8LC-800

    240

    355

    187

    285

    116

    58

    40

    Note: The mounting hole cut-out size is the reference size, and the customer can adjust the actual cut-out size according to the installation method.

    6.1 The circuit breaker should be installed vertically and fixed with screw through the mounting hole.

    6.2 The user selects standard cross-sectional area wire based on product current specification and connect the wire to the circuit breaker(the copper connector must be equipped). The upper terminal of the circuit breaker(right zero 1,3,5,N;left zero N, 1, 3, 5)is the power input terminal of the main circuit, and the lower terminal(right zero 2,4,6,N; left zero N,2,4,6)is the output terminal. The neutral line(zero line) of the power supply must be connected to the "N" terminal.

    6.3 After installation, power on the circuit breaker. If the status indicator light is not on, it indicates that it is in the disconnected state. Press the "Closing" button to start the circuit breaker closing. When the "Closing" status indicator light is on, it indicates successful closing.

    7.Description of protection characteristic

    7.1 Digital tube type

    7.1.1 Action value setting range

    Table 1: Overload long delay parameter setting

    2061FB90-9546-487c-85C0-9560E4B826DE

    7.1.2 Action characteristic

    Table 2: Protection action characteristic

    DEE2D133-1DEF-4725-AEA4-1417AD9F2043

    7.1.3 Delay characteristic

    Overload protection is carried out according to the inverse time limit characteristic:T=(6Ir1/I)2tL Delay precision:±10% Among which, T is the action time value, Ir1 is the set value for long delay protection, I is the fault current, and tL is the set value for long delay time

    7.2 Short circuit short delay protection

    Short circuit short delay protection prevents impedance short circuit in the distribution system, and trip delay is to achieve selective protection.

    7.2.1 Short circuit short delay protection related parameter setting

    Table 3: Short circuit short delay parameter setting

    Parameter setting Set value Factory set value
    Short delay action
    current set value Ir2
    2Ir2~10Ir2 adjustable 6Ir2
    Short delay time
    set value ts
    0.1s-1.0s adjustable 0.4s

    7.2.2 Short circuit short delay protection action characteristic

    Table 4: Short circuit short delay action characteristic

    Characteristic Fault current multiple Trip time Delay error
    Non-action 
    characteristic
    ≤0.85Ir2 Non-action +40ms
    Action 
    characteristics
    >1.15Ir2 Delay action +40ms

    7.3 Instantaneous protection

    7.3.1 Short-circuit instantaneous protection related parameter setting 

    Table 5: Instantaneous parameter setting

    Parameter setting Factory set value
    Instantaneous action 
    current set value Ir3
    4li-12li adjustable 10Ir1

    7.3.2 Short circuit instantaneous protection action characteristic 

    Table 6: Instantaneous action characteristic

    Characteristic Current multiple (I/Ir3) Trip time Delay error
    Non-action 
    characteristic
    ≤0.8 Non-action -
    Action 
    characteristics
    >1.2 Instantaneous action -

    7.4 Residual current protection characteristic

    7.4.1 Gear setting range

    Parameter Set value(mA) Factory set value
    Residual operating 
    current I n
    30 (non-delay only) 
    50/100/150/200/300/500/700/900/1000/OFF graded adjustment(delay type), automatic tracking
    500mA

    7.4.2 Action characteristic

    01CAEDFC-CBC3-434c-A199-4717BFA75501

    7.4.3 Automatic gear mode

    Gear value and floating value in automatic gear mode:

    When the residual current exceeds the floating value of the gear but does not reach its operating value and remains stable for 60s, the gear will float up one gear, and so on, until the maximum gear is reached; when the residual current is less than the floating value of the next gear and remains stable for 120s, the gear will float down one gear, and so on until the minimum gear is reached. Taking the "Automatic 2" gear as an example, the initial residual current of the line is 100mA. When the circuit breaker is energized and the gear is automatically set to 300mA. When the residual current increases to above 150mA and stabilizes for 60s, the gear changes to 500mA gear; when the residual current decreases to below 150mA and stabilizes for 120s, the gear changes to 200mA.

    8. Characteristic curve of electronic type overcurrent short circuit protection

    EA8AAB37-8A8F-416c-A743-A5AF28A9ABCC

    9.Panel introduction

    9.1 Meaning of status indicator light

    (1)Power light: it indicates the power supply status

    (2) "Closing" light: After the circuit breaker is closed, the "Closing" light will light up.

    (3)"Fault light": When there is undervoltage, phase failure, overvoltage, current fault and manual opening, the light will light up.

    (4)Communication light: When there is communication function, the communication light flashes.

    (5)Alarm light: When the leakage alarm function is activated, the alarm light is on, and the light flashes when the leakage exceeds the set value.

    9.2.2Key description

    (1) [Opening]key: Press this key to enter the opening state of the controller.

    (2) [Closing]key: Press this key to automatically turn on the controller.

    (3) [Return]key: Press this key to exit the parameter setting state and enter the normal detection operation state.

    (4) [Settings]Key: Press this key to enter the parameter setting state and perform parameter setting.

    (5) [Up, Down]keys: The user can select the desired option in the menu.

    (6) [Confirm]key: After setting the parameter, press this key to save the setting.

    (7) [Test trip]key: Press this key to simulate a leakage fault and the controller will turn off.

    10. Introduction to the operation interface

    10.1 Digital tube type

    10.1.1 Main menu

    Press the Menu key to enter the menu interface, as follows:

    1. Function setting ( ) 2. Parameter settings ( ) 3. Fault recording( ) 

    4. Number of faults ( ) 5. Self check setting( ) 6.Factory maintenance( )

    8900C3AA-1B18-49f5-8DAC-86E85ECFB9EB
    8B7E7D44-7BC0-4d90-8B8E-1F3EB36A75ED

    10.1.2 Under function setting ( ), press Confirm and enter the 

    password(initial: 0000) to enter the function setting interface. Press the 

     or keys to select the function setting item, press the Menu key, the 

    value will remain on, and then press Confirm to activate the function. The 

    flashing display of the parameter indicates that the function is in the exit state, 

    and the constant illumination of the parameter indicates that the function is in 

    use. As shown in Figure 7, the leakage alarm is turned on. Press the Return 

    key to return to the menu interface.

    3D697A87-B6E2-4ea0-B5BD-43E813A4AA2C
    Function setting Default value
    Leakage alarm OFF After the leakage alarm function 
    is turned on: flashing: it indicates 
    that the leakage is greater than 
    the set value, constantly on: it 
    indicates that the leakage alarm 
    function has been turned on. 
    (Note: Long press and hold the 
    Return button for 3s to turn on 
    or off the leakage alarm function. 
    When the leakage alarm function 
    is turned on, the product only 
    alarms and does not trip.)
    Warning: The leakage alarm 
    function cannot be activated 
    without the approval of the 
    power supply management 
    department
    Automatic tracking OFF
    Abrupt change protection OFF
    Special wave protection OFF
    Automatic closing ON
    Power-on test closing ON
    Overvoltage protection ON
    Undervoltage protection OFF
    Phase failure protection OFF
    Full voltage loss function ON
    Current protection function ON
    Short circuit short delay function setting ON
    Current imbalance OFF
    Zero line loss protection function OFF
    External breaking function ON For maintenance personnel only

    10.1.3 Under parameter setting ( ), press Confirm and enter the

    password(initial:0000) to enter the parameter setting interface. Press Confirm , 

    the value will flash, press the or keys to modify the parameter, and 

    press the Confirm key to confirm the parameter. As shown in Figures 8 and 9, 

    press the Return button to return to the menu interface.

    6AF93A69-CD29-4fa7-813E-432F9A97B8EC
    24712212-DEC6-49cc-A4AF-62A3593B2A44

    10.1.4 Under fault record( ), press Confirm to enter the fault and trip

    information query interface. Press the Confirm key to enter the fault cause, and

    press the Menu to inquire about the trip cause and time. As shown in Figures 10

    and 11, press the Return button to return to the main menu interface.

    941E4BD5-C8C4-445c-9412-D6221EABB9FF

    10.1.5 Under number of faults ( ), press Confirm to enter the fault

    frequency query interface. It will display the total number of trips and the number 

    of blocked trips. As shown in Figures 12 and 13. Press the Return key to return 

    to the main menu interface.

    7BB73D9B-0F76-4500-92C9-3BD6C7B34F6D

    10.1.6 Factory maintenance( ) is only for the manufacturer's technical and 

    maintenance personnel to operate.

    10.2 Liquid crystal type

    10.2.1 It displays product version information upon startup

    B418F1F1-B29A-4866-A670-22C5D1C4407D

    This interface mainly displays software and hardware version information

    10.2.2 Real time information display

    F571278B-A47B-48cc-B52E-B99E59475649

    This interface mainly displays the operating status of the switch, real-time voltage, real-time current, real-time leakage, leakage gear and system time ->00/02: it indicates the number of leakage/blocking times 
    Button operation instruction
    Up/Down :Page flipping display

    Menu : it enters the main menu

    10.2.3 Main menu

    297D1C86-5206-4f52-AFD8-4FBBB37FC3EC

    This interface is the main menu, and various submenus can be accessed 

    from this interface 

    Button operation instruction 

     Up/Down : It moves the cursor

     Menu : It enters submenu

     Return : It returns to the real-time display interface

    10.2.4 Login interface

    4E079415-7AAC-43dd-BFCB-5F0884E0DE87

    The default password is 0000 (press the Confirm button 4 times continuously)

    Button operation instruction

     Up/Down :It moves the selection cursor

     Confirm : It enters password

     Return : It returns to the main menu

    10.2.5 Parameter setting interface

    05A939AA-EC70-4f58-BA6F-506AE108ACFA

    Under this interface, the user can set the opening and closing of various functions

    Button operation instruction

     Set : It moves the setting item cursor

     Confirm : It enters/exits(parameter storage)setting status

     Up/Down : Setting adjustment 

     Return : It returns to the main menu

    10.2.6 Parameter setting interface

    48E6EB48-8912-459d-BA4E-3599E714F761

    Set the functional parameters on this interface, and then press the Confirm

    button to save the operation instruction 

     Up/Down :It moves the setting item cursor

     Confirm : It enters/exits(parameter storage)setting status

     Return : It returns to the main menu

    10.2.7 Fault record interface

    6844DA59-E3B7-4946-A842-4BFF0982B2DC

    This interface can query the historical event record of the switch, as well as the fault voltage, current and leakage data at the time of the event occurrence, as well as the specific time of the event occurrence. 

    Button operation instruction

     Up/Down : It switches record information

     Return : It returns to the main menu

    10.2.8 Number of faults interface

    FA6F7853-E5AD-4aeb-8AB4-7A951EBCEDF0

    This interface displays the total number of trips, blocking trips, leakage trips, and overcurrent trips. 

    Button operation instruction 

     Return : It returns to the main menu

    10.2.9 Factory maintenance menu

    Under this menu, the parameter coefficient can be fine tuned

    Note: This function is used for internal debugging within the company and is not recommended for non special circumstances

    11.Common fault display

    DCBF68C1-D88A-4731-AF9B-8069AF3CA099
    5077D038-1A28-4733-A1AA-EB7CD665F59E
    3964B0FE-E717-409e-B2DD-BD8D9360292F

    11.10 Opening failure, as shown in Figure 24 on the screen;

    14EBD761-E2CD-4ff7-ACCE-13760F522E22

    12. Precaution

    12.1 After the residual current circuit breaker is put into normal operation, it 

    should be tested once a month and recorded.

    12.2 It is not allowed to test trip by short circuiting the phase line to the 

    neutral line to avoid causing short-circuit current and burning the device. A

    resistor of about 1KΩ should be connected in series (determined according to 

    regulation).

    12.3 Protection cannot be provided for electric shock hazards caused by 

    simultaneous contact with two wires of the protected circuit.

    12.4 Do not unseal the circuit breaker without authorization, otherwise you 

    should bear the consequences.

    13. Description of external terminals

    External port description:

    Due to customer customization or standard change, the external port may not be consistent with the figure below. Please 

    refer to the terminal label on the product body for accuracy. We apologize for any inconvenience caused. The external terminals are shown in the figure

    7E0E1738-7A71-43d2-8FB4-8035E92A2FFE

    14. Common fault analysis and troubleshooting method

    Fault 
    category
    Fault phenomenon Cause analysis Troubleshooting method
    Unable to 
    put into
    operation
    Indicator light
    does not light up
    1. Check if the power supply is 
    connected properly
    2. The controller switch is not . 
    turned on
    1. Connect the power supply properly. 
    2. Turn on the controller switch
    When pressing 
    the "Close" button, 
    the circuit breaker 
    cannot be closed
    1. Check whether the zero line
    is connected to “N” terminal 
    2. The controller switch is not 
    turned on
    1. Check the zero line
    2. Turn on the controller switch
    It trips immediately 
    after closing
    1.Mixed use of zero and ground line
    2. Excessive load leakage
    3. Undervoltage, overvoltage and 
    phase loss
    1. Check the circuit and electrical equipment. 
    2. Check the circuit for leakage fault. 
    3. Check the circuit for fault or turn off 
    relevant protection
    Refusal to 
    move
    When pressing the 
    test button, 
    it doesn't trip
    1. Controller switch is not turned on 
    2. Leakage function is turned off
    1. Turn on the controller switch
    2. Turn on the leakage protection function
    When pressing the 
    test button, it can trip, 
    but it does not trip 
    the actual bulb test
    The neutral point of the distribution 
    transformer is not grounded or has 
    poor contact
    Check neutral grounding

    Dear users:

    The leakage alarm function is enabled and is only used by professional personnel for maintenance. It is prohibited to start after the product is put into normal operation

    15. Accessory list

    1. 1 operating manual;

    2. 1 manual wrench;

    3. 6 arc barriers;

    4. Mounting screws;

    5. 1 7P wiring terminal.

    B0642F4B-9D1E-4356-B3F1-57888C21A0AE
    6C3B6454-6F7C-44da-BC5B-9840094BA073
    3A150969-4228-4639-A76D-7EF6EEC35C57
    749DC6AE-F6FD-4461-9F17-B1BCC464BE06
    F8CC2BD4-B44D-4944-BC8A-590F8570AFB5

    Contact Us

    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Support Center 24/7
    0086 173 1658 0160
    Write to Us
    yjq@cdada.com
    Our Location
    171 Yezhuang road, Fengxian District, Shanghai, China
    Related Products
    Shanghai DADA Electric Co., Ltd.
    Acknowledged as one of the most respected nationwide manufacturers and exporters of low voltage circuit breakers in China.
    Social media
    CONTACT US
    Contact Person: Joker Yang
    Tel: +86 173 1658 0160
    Contact Person: Charlotte Weng
    Tel: +86 151 6747 7792
    Address: 171 Yezhuang Road, Fengxian District, Shanghai, China
    Customer service
    detect