Residual current operated circuit breakers with overcurrent protectionDABL-40 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
Product Description
Residual current operated circuit breakers with overcurrent protectionDABL-40are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.
They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series.
The most subtle electric shock hazard protection in case of direct contact with conducting parts.
Independent contact position indicator.
Wide range of operating temperatures from –25 to +40° С.
Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.
“TEST” button for checking the device’s operation and accuracy of connection.
DABL dimensions correspond to 2-modular item at the expense of constructive elements placement.
Boosted capability of 6 kA provides for installing AVDTs as incoming protection switches.
Specifications
|
RCBO DABL-40/63 Electronic type |
|||
|
For protection of general power distribution (IEC/EN 60898-1) |
|
||
|
Poles of number |
1P+N |
||
|
Electrical performance |
|||
|
Rated current In( A ) |
6-63A |
||
|
Release type |
Electronic type |
||
|
Functions |
Protection against short circuit , leakage ,overload, over voltage,isolation |
||
|
Type of residual current |
AC and A |
||
|
Rated frequency f ( Hz) |
50-60Hz |
||
|
Rated working voltage Ue (V) AC |
230/400 |
||
|
Rated residual current motion I△n( mA) |
10,30,100,300 |
||
|
Rated residual current no-motion I△no( mA) |
5,15,25,50,300 |
||
|
cosф |
0.5 |
||
|
Insulation voltage Ui |
500V |
||
|
Rated impulse withstand voltage Uimp |
6KV |
||
|
Instantaneous tripping type |
B/C/D |
||
|
Rated short circuit Icn(kA) |
6/10 |
||
|
Service life(O~C) |
Mechanical |
12000 |
|
|
Electrical |
6000 |
||
|
Connection and installation |
|
||
|
Protection degree |
IP40 |
||
|
Wire mm² |
1~25 |
||
|
Working temperature (with daily average≤35℃) |
-5 ~+40℃ |
||
|
Resistance to humidity and heat |
Class 2 |
||
|
Altitude above sea |
≤2000 |
||
|
Relative humidity |
+20℃ , ≤90% ;+40℃ , ≤50% |
||
|
Pollution degree |
2 |
||
|
Installation environment |
Avoid obvious shock and vibration |
||
|
Installation class |
Class Ⅱ , Class Ⅲ |
||
|
Combination with accessories |
|||
|
Auxiliary contact |
Yes |
||
|
Alarm contact |
Yes |
||
|
ALT+AUX |
Yes |
||
|
Shunt release |
Yes |
||
|
Undervoltage release |
– |
||
|
Overvoltage release |
Yes |
||
|
|
a |
35 |
|
|
b |
80.4 |
||
|
c |
72 |
||
Product Features
| Combined circuit with an electronic module of differential protection, D-class varistor and integrated circuit breaker of DAB7-63 series ensures 4 types of protection: from residual current (leakage current), short circuit; overload and surge overvoltage. | Welding deposition of silver-bearing composite provides for boosting the contact block’s wear-resistance and lowering the transient one. |
| Main circuit status indicator provides exact information on the contacts status independently from lever position. | Wide range of operating temperatures from –25 to +40° С contributes to applying this switch in different climatic zones. |
| “TEST” button for checking the device’s operation and accuracy of connection. | Notches on terminal clamps allow lowering thermal losses and boosting the mechanical stability of connection. |
| Boosted screw head dimension with cross-functional crest (+,–) helps to facilitate mounting and prevents the screws from falling out during the installation. | |
Contact Us