Residual current operated circuit breakers with overcurrent protectionDABL-40 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    Residual current operated circuit breakers with overcurrent protectionDABL-40are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.

    They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.

    Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series.

    The most subtle electric shock hazard protection in case of direct contact with conducting parts.

    Independent contact position indicator.

    Wide range of operating temperatures from –25 to +40° С.

    Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.

    “TEST” button for checking the device’s operation and accuracy of connection.

    DABL dimensions correspond to 2-modular item at the expense of constructive elements placement.

    Boosted capability of 6 kA provides for installing AVDTs as incoming protection switches.

    dabl-63 2p+n rcbo circuit breaker

    Specifications

    RCBO DABL-40/63 Electronic type

    For protection of general power distribution (IEC/EN 60898-1)

     

    Poles of number

    1P+N

    Electrical performance

    Rated current   In( A )

    6-63A

    Release type

    Electronic type

    Functions

    Protection against short circuit , leakage ,overload, over voltage,isolation

    Type of residual current

    AC and A

    Rated frequency   f ( Hz)

    50-60Hz

    Rated working voltage Ue (V) AC

    230/400

    Rated residual current motion   I△n( mA)

    10,30,100,300

    Rated residual current no-motion  I△no( mA)

    5,15,25,50,300

    cosф

    0.5

    Insulation voltage  Ui

    500V

    Rated impulse withstand voltage   Uimp

    6KV

    Instantaneous tripping type

    B/C/D

    Rated short circuit Icn(kA)

    6/10

    Service life(O~C)

    Mechanical

    12000

    Electrical

    6000

    Connection and installation

     

    Protection degree

    IP40

    Wire                                             mm²

    1~25

    Working temperature (with daily average≤35℃)

    -5 ~+40℃

    Resistance to humidity and heat

    Class 2

    Altitude above sea

    ≤2000

    Relative humidity

    +20℃ , ≤90% ;+40℃ , ≤50%

    Pollution degree

    2

    Installation environment

    Avoid obvious shock and vibration

    Installation class

    Class Ⅱ , Class Ⅲ

    Combination with accessories

    Auxiliary contact

    Yes

    Alarm contact

    Yes

    ALT+AUX

    Yes

    Shunt release

    Yes

    Undervoltage release

    Overvoltage release

    Yes

    DABL-63 6KA Residual Current Operated Circuit Breaker 5Dimensions(mm)                                            (WxHxL)

    a

    35

    b

    80.4

    c

    72

    Product Features

    Combined circuit with an electronic module of differential protection, D-class varistor and integrated circuit breaker of DAB7-63 series ensures 4 types of protection: from residual current (leakage current), short circuit; overload and surge overvoltage.Welding deposition of silver-bearing composite provides for boosting the contact block’s wear-resistance and lowering the transient one.
    Main circuit status indicator provides exact information on the contacts status independently from lever position.Wide range of operating temperatures from –25 to +40° С contributes to applying this switch in different climatic zones.
    “TEST” button for checking the device’s operation and accuracy of connection.Notches on terminal clamps allow lowering thermal losses and boosting the mechanical stability of connection.
    Boosted screw head dimension with cross-functional crest (+,–) helps to facilitate mounting and prevents the screws from falling out during the installation.

    Contact Us

    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Support Center 24/7
    0086 173 1658 0160
    Write to Us
    yjq@cdada.com
    Our Location
    171 Yezhuang road, Fengxian District, Shanghai, China
    Related Products
    Shanghai DADA Electric Co., Ltd.
    Acknowledged as one of the most respected nationwide manufacturers and exporters of low voltage circuit breakers in China.
    Social media
    CONTACT US
    Contact Person: Joker Yang
    Tel: +86 173 1658 0160
    Contact Person: Charlotte Weng
    Tel: +86 151 6747 7792
    Address: 171 Yezhuang Road, Fengxian District, Shanghai, China
    Customer service
    detect