loading

CDADA - Professional circuit breaker manufacturer since 1984

DAM1L-125/160/250/400/630 Earth Leakage protection circuit breaker (ELCB) 1
DAM1L-125/160/250/400/630 Earth Leakage protection circuit breaker (ELCB) 2
DAM1L-125/160/250/400/630 Earth Leakage protection circuit breaker (ELCB) 3
DAM1L-125/160/250/400/630 Earth Leakage protection circuit breaker (ELCB) 4
DAM1L-125/160/250/400/630 Earth Leakage protection circuit breaker (ELCB) 1
DAM1L-125/160/250/400/630 Earth Leakage protection circuit breaker (ELCB) 2
DAM1L-125/160/250/400/630 Earth Leakage protection circuit breaker (ELCB) 3
DAM1L-125/160/250/400/630 Earth Leakage protection circuit breaker (ELCB) 4

DAM1L-125/160/250/400/630 Earth Leakage protection circuit breaker (ELCB)

DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology.Protected moulded case type circuit breaker.The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated In a power distribution network with a current of 10A~500A and a rated working voltage of 380V/400V, it is used to distribute electric energy and protect the overload and short circuit of lines and power equipment.Under normal conditions,It can also be used for infrequent switching of lines.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    This circuit breaker also has the following protection:

    It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection.

    Provide protection against the danger of increasing ground voltage due to insulation damage;

    Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection.

    Circuit breakers with rated current of 500A and below can also be used for infrequent start, break off during operation and overload and short circuit protection of squirrel cage motors.

    DAM1L series circuit breakers can be equipped with electric accessories and mechanical accessories for various purposes, such as separately excited tripping device, auxiliary contact, alarm contact and rotating handle operating mechanism.

    This series of circuit breakers are widely used in construction, transportation, tunnel, residence, etc.The delay type in this series of circuit breakers is used for branch lines Distribution of roads;Adjustable type is used to adjust the residual action current or disconnection time on site.

    Earth leakage circuit breaker(ELCB&CBR)

    Specifications

    Residual current circuit breaker basic parameters
    COSφ Rated current of remnant motionI△n (mA) Rated current of remnant no-motion I△no (mA) Max-Breaking time(S)
    0.2 100,300,500 50,150,250 0.05,0.5,0.8
    Rated residual operating current(mA) Rated no tripping current value.I△no(mA) Residual current value range. (mA)0.5x(I△n+I△no)±0.21△n
    30 15mA 18mA-27mA
    100 50mA 60mA-90mA
    300 150mA 180mA-270mA
    500 250mA 300mA-450mA
    1000 500mA 600mA-900mA
    Earth-Leakage Circuit Breakers(ELCB)
    Model DAM1-125L DAM1-160L
    Breaking Capacity Code B N S B N S
    Rated Current of Frame size-Inm (A) 125A 160A
    Rated Current-In(40,50 or 55℃)(A) 10-12,5-16-20-25-32(30)-40-50-63(60)-80-100-125A 10-12,5-16-20-25-32-40-50-63-80-100-125-160(150)A
    Ui(V) 690V 690V
    Ue(V) 400V 400/415V
    Number of Pole 4P 4P
    lcu(KA) 25  35  50  25  35  50 
    lcs(KA) 12.5  17.5  37.5  12.5  26.25  37.5 
    lcm(peak)/cosφ(KA) 40/0.3 73.5/0.25 105/0.25 41/0.3 73.5/0.25 110/0.25
    (I△m)KA/cosφ 9/0.5 19/0.5
    Residual current threshold(mA) 100-300-500 100-300-500
    Time delay(ms) 50-500-800 50-500-800
    Uimp(V) 10000  8000 
    Dielectric Properx(V) 2500  3000 
    lonization distance(mm) ≤30/0 ≤30/0
    Endurance Total Cycles 8000  8000 
    Electrical Life 1000  1000 
    Mechanical Life 7000  7000 
    Category (EN 60947-2/IEC 60947-2) Main circuit A/0 A/0
    Auxiliary circuit AC-15 AC-15
    Under Voltage Release
    Shunt Release
    Auxiliary Contact
    Alarm Contact
    Auxiliary Contact and Alarm Contact
    Handle Operation Mechanism
    Electrical Operastion Mechanism
    Terminal cover    
    Phase seperator    
      W
    (mm)
    3P
    4P 101  120 
    L
    (mm)
    3P
    4P 155  120 
    H
    (mm)
    3P
    4P 70  70 
    Weight Fixed version 3P/4P
    Plug-in version 3P/4P
    Draw out version 3P/4P
    DAM1-250L DAM1-400L
    N S H G N S H G
    250A 400A
    63-80-100-125-160(180)-200(225)-250(320)A 250-315(350)-400-500A
    690V 690V
    400/415V 400/415V
    4P 4P
    35 50 65 85 35 50 70 85
    26.25 37.5 48.75 51 26.25 37.5 52.5 52.5
    77/0.25 114/0.25 143/0.2 178/0.2 70/0.25 110/0.25 154/0.2 187/0.2
    12/0.3 19/0.5
    100-300-500 100-300-500
    50-500-800 50-500-800
    8000 8000
    3000 3000
    ≤30/0※ ≤60/0※
    8000 5000
    1000 1000
    7000 4000
    A/B A/B
    AC-15 AC-15
    140 184
    210 254
    103.5 103.5
      41.5/5.5 5.1/7.1
      4.6/6 6.5/8.5
      5/6.4 6.5/8.7

    · Icu:O-t-CO test(O:Open maneuver,CO:Close-Open maneuver,t:Waiting duration)

    · Ics:O-t-CO-t-CO test(O:open maneuver,CO:Close-Open maneuver,t:Waiting duration)

    Product Features

    Range: 10A to 500A(AC)

    integral structure, small volume, high breaking capacity, safe and reliable.

    Adjustable magnetic setting(0.8-1times)In.

    Push to trip button provision.

    Separate main and arcing contacts

    Can be adjusted the residual action current or disconnection time according to the actual use.

    Strong anti-interference ability.

    4 (17)
    2 (34)

    Wide range of accessories.

    The working power of the residual current protection circuit of this series of circuit breakers is supplied by the multi-phase power supply (the working power of the protection circuit of early products is supplied by the single-phase power supply)the residual current protection circuit of the device can still operate normally.When the operating power voltage of the circuit breaker’s residual current protection circuit is reduced to 50V, the circuit breaker’s residual current protection circuit can still work normally.(I coherence n=30mA)

    This series of circuit breakers are classified into B type (i.e., basic breaking capacity) (Inm less than 100), S type (i.e., standard breaking capacity) and H type (i.e High score breaking capacity (Inm > 160) can be used in different situations.

    Contact Us

    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Support Center 24/7
    0086 173 1658 0160
    Write to Us
    yjq@cdada.com
    Our Location
    171 Yezhuang road, Fengxian District, Shanghai, China
    Related Products
    Shanghai DADA Electric Co., Ltd.
    Acknowledged as one of the most respected nationwide manufacturers and exporters of low voltage circuit breakers in China.
    Social media
    CONTACT US
    Contact Person: Joker Yang
    Tel: +86 173 1658 0160
    Contact Person: Charlotte Weng
    Tel: +86 151 6747 7792
    Address: 171 Yezhuang Road, Fengxian District, Shanghai, China
    Customer service
    detect