loading

CDADA - Professional circuit breaker manufacturer since 1984

DC Surge Protective Devices 1
DC Surge Protective Devices 2
DC Surge Protective Devices 3
DC Surge Protective Devices 1
DC Surge Protective Devices 2
DC Surge Protective Devices 3

DC Surge Protective Devices

SPD lightning protection module (surge protector) is mainly suitable for 50Hz (or 60Hz) impact flow capacity is not greater than (60 kA) electrical circuit, limit transient overvoltage amplitude, absorption, elimination, consumption or discharge of surge current energy, make the protected electrical components from an overvoltage category to another low overvoltage category, suitable for household, and similar places electrical appliances in the line induction lightning overvoltage, operating overvoltage protection role.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    Applicable principles

    SPD lightning protection module (surge protector) is mainly suitable for 50Hz (or 60Hz) impact flow capacity is not greater than (60 kA) electrical circuit, limit transient overvoltage amplitude, absorption, elimination, consumption or discharge of surge current energy, make the protected electrical components from an overvoltage category to another low overvoltage category, suitable for household, and similar places electrical appliances in the line induction lightning overvoltage, operating overvoltage protection role.

    3 (21)
    1 (37)

    Normal working conditions and installation conditions

    ●  Ambient temperature is-40℃ – + 70℃.

    ●  The elevation shall not exceed 2000m.

    ●  Relative humidity is not greater than 90% (25℃).

    ●  Installation mode is matched with the TH35mm wide guide rail.

    ●  Applicable ground pump flow “IT” ” TT.TS,TN-N-S”

    ●  The inclination of with the vertical plane does not exceed 5.

    ●  No impact vibration or no shaking place

    ●  No medium without explosion risk, and no gas and dust medium enough to corrode metal and destroy insulation.

    Main structure and working principle

    In the photovoltaic power generation system, there are protectors between the grounding in the positive and negative electrode lines. Under normal circumstances, the protector is in a state of high resistance. When the power grid is due to lightning or other original, due to the surge voltage, the protector will immediately turn on at the nanosecond level, within time, introducing the surge voltage into the earth, so as to protect the electrical equipment on the power grid. When the surge voltage passes through the protector, and the protector disappears back to the high resistance state again, so as not to affect the normal operation of the power grid.

    2 (29)

    Specifications

    Model SPD-PV
    Rated Voltage (DC) 500V~1200V
    Maximum continuous
    working voltage uc (DC)
    PV1000V PV1200 PV1500V
    Protection level C(two stage)
    Nominal discharge
    current I In (8 / 20 uS) (kA)
    20
    Maximum Discharge Current Imax (8 / 20 uS) (kA) 40
    Protection level up (kV) 3.2kV 4.5kY 5.0kV
    Response time (nS) ≤25
    ambient humidity -40℃-+70℃
    Housing color module / base white
    Maximum connection diameter (mm ²) 35 hard lines or multiple strands
    Suggested wiring (mm ²) 4~25
    Circuit breaker type selection is recommended 125A~250A
    Install 35mm electrical guide

    Product Features

    Installation method and matters needing attention

    undefined
    Excellent breaking ability
    The power supply must be disconnected during the installation.
    undefined
    Dual wiring function of conductor and bus bar
    There must be corresponding air switches or fuses in series at the front end of the surge protector.
    undefined
    Fast closure, long life
    The connecting wire should be used with the same capacity as the power line or greater than the power line, the total length should be controlled within 0.5 meters, The shorter the wire length, the better.
    undefined
    Convenient installation and disassembly

    Fault judgment of the surge protector:
    ① The indicator window of the module is green (normal). When the module deteriorates, the indicator window should be replaced in time;
    ② Surge protector can be equipped with (FS) remote remote communication alarm, remote communication touch There is a constant open and one constant close, one module or multiple modules of the surge protector failure, the contact will close, send a fault alarm signal, indicating that the module failure must be replaced.
    ③ Always check the air switches or fuses connected in series on the line.

    Contact Us

    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Support Center 24/7
    0086 173 1658 0160
    Write to Us
    yjq@cdada.com
    Our Location
    171 Yezhuang road, Fengxian District, Shanghai, China
    Related Products
    Shanghai DADA Electric Co., Ltd.
    Acknowledged as one of the most respected nationwide manufacturers and exporters of low voltage circuit breakers in China.
    Social media
    CONTACT US
    Contact Person: Joker Yang
    Tel: +86 173 1658 0160
    Contact Person: Charlotte Weng
    Tel: +86 151 6747 7792
    Address: 171 Yezhuang Road, Fengxian District, Shanghai, China
    Customer service
    detect